Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

2Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from ∼ 70 ns to ∼ 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.

Cite

CITATION STYLE

APA

Anderlini, L., Anelli, M., Archilli, F., Auriemma, G., Baldini, W., Bencivenni, G., … Vorobyev, A. (2016). Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency. Journal of Instrumentation, 11(4). https://doi.org/10.1088/1748-0221/11/04/P04010