Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last.

Cite

CITATION STYLE

APA

Li, P., Fu, X., Luo, L., & Yu, Q. (2014). A New Analyzing Method of Single Event Latch-Up Protection Circuit Based on Current Comparing and Its Performance Verification. Journal of Modern Physics, 05(06), 387–393. https://doi.org/10.4236/jmp.2014.56050