Two-year outcomes of a cardiac microcurrent device in chronic heart failure: A first-in-human pilot study

2Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims: In heart failure patients, altered myocardial electrical fields linked to oedema may impair left ventricular function. While short-term use of implanted microcurrent generators (C-MIC) has shown promise, long-term effects remain unclear. This study assessed the safety and efficacy of C-MIC use beyond the initial 6 month pilot period. Methods: Patients from the initial C-MIC pilot study who were alive at 6 months were screened for 2 year follow-up. The primary endpoint included rates of all-cause, cardiac- and device-related mortality, all-cause, cardiac and device related hospitalizations, along with adverse events, device malfunctions and exchanges. Secondary endpoints evaluated device performance via left ventricular ejection fraction (LVEF), 6 min walk distance, New York Heart Association (NYHA) class and SF-36 quality-of-life scores and the need for prolonged therapy. Results: Of the 10 patients enrolled in the initial study, 7 were enrolled in follow-up (mean age 52.4 ± 7.6 years, NYHA Class III and mean LVEF 31.7 ± 3.7%). No device-related adverse events occurred. One non-cardiac, non-device related death was reported at 18 months. Improvement in LVEF of 11.60% [95% confidence interval (CI): 5.64–17.56, P < 0.001] from baseline to 6 months was maintained at 2 years post-C-MIC deactivation, with a sustained increase of 12.56% from baseline (95% CI: 4.67–20.45, P = 0.002). Similarly, the 6 min walk distance improved by 206.35 m at 6 months (95% CI: 161.32–251.39, P < 0.0001) and remained at 191 m above baseline at 2 years (95% CI: 131.83–250.99, P < 0.0001). Improvements in NYHA functional class and SF-36 quality-of-life scores observed at 6 months were also preserved throughout the 2 year follow-up. One patient required C-MIC reactivation. Conclusions: Long-term use of the C-MIC device appears safe with sustained improvements in NYHA class, LVEF, 6 min walk distance and quality of life, supporting the long-term therapeutic potential of microcurrent therapy.

Cite

CITATION STYLE

APA

Kosevic, D. B., Radak, U., Vukovic, P., Schmitto, J. D., Brandes, K., Goettel, P., … Peric, M. (2025). Two-year outcomes of a cardiac microcurrent device in chronic heart failure: A first-in-human pilot study. ESC Heart Failure, 12(5), 3264–3275. https://doi.org/10.1002/ehf2.15369

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free