MRI-based computational hemodynamics in patients with aortic coarctation using the lattice Boltzmann methods: Clinical validation study

38Citations
Citations of this article
78Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To introduce a scheme based on a recent technique in computational hemodynamics, known as the lattice Boltzmann methods (LBM), to noninvasively measure pressure gradients in patients with a coarctation of the aorta (CoA). To provide evidence on the accuracy of the proposed scheme, the computed pressure drop values are compared against those obtained using the reference standard method of catheterization. Materials and Methods: Pre- and posttreatment LBM-based pressure gradients for 12 patients with CoA were simulated for the time point of peak systole using the open source library OpenLB. Four-dimensional (4D) flow-sensitive phase-contrast MRI at 1.5 Tesla was used to acquire flow and to setup the simulation. The vascular geometry was reconstructed using 3D whole-heart MRI. Patients underwent pre- and postinterventional pressure catheterization as a reference standard. Results: There is a significant linear correlation between the pretreatment catheter pressure drops and those computed based on the LBM simulation,r=.85, < p .001. The bias was -0.58 ± 4.1 mmHg and was not significant (P=0.64) with a 95% confidence interval (CI) of -3.22 to 2.06. For the posttreatment results, the bias was larger and at -2.54 ± 3.53 mmHg with a 95% CI of -0.17 to -4.91 mmHg. Conclusion: The results indicate a reasonable agreement between the simulation results and the catheter measurements. LBM-based computational hemodynamics can be considered as an alternative to more traditional computational fluid dynamics schemes for noninvasive pressure calculations and can assist in diagnosis and therapy planning. Level of Evidence: 3. J. Magn. Reson. Imaging 2017;45:139–146.

Cite

CITATION STYLE

APA

Mirzaee, H., Henn, T., Krause, M. J., Goubergrits, L., Schumann, C., Neugebauer, M., … Hennemuth, A. (2017). MRI-based computational hemodynamics in patients with aortic coarctation using the lattice Boltzmann methods: Clinical validation study. Journal of Magnetic Resonance Imaging, 45(1), 139–146. https://doi.org/10.1002/jmri.25366

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free