Blocking ELISA to distinguish pseudorabies virus-infected pigs from those vaccinated with a glycoprotein gIII deletion mutant.

15Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A blocking enzyme-linked immunosorbent assay (ELISA) test has been developed to distinguish pseudorabies virus (PRV)-infected pigs from those immunized with a glycoprotein g92(gIII) deletion mutant, PRV(dlg92dltk). The blocking ELISA utilizes 96-well microtiter test plates coated with a cloned PRV g92(gIII) antigen, a mouse monoclonal antibody against gIII antigen (moMCAgIII): horseradish peroxidase (HRPO) conjugate, and undiluted test sera. Analyses can be completed in less than 3 hours with results printed out by an automated plate reader. Analyses on over 300 pig sera from PRV-free farms, on sera from other species, and on control sera containing antibodies to microorganisms other than PRV showed that the ratio of the optical density at 405 nm for the test sample to the optical density at 405 nm for the negative control (S/N value) was greater than 0.7 for all sera. No false positives were identified. Likewise, the S/N values were greater than 0.7 for over 400 sera obtained from pigs vaccinated twice with more than 1,000 times the standard PRV (dlg92dltk) dose or 1-4 times with the standard dose (2 x 10(5) TCID50/pig). Following challenge exposure to virulent PRV, the S/N values of the vaccinates were 0.1, showing that g92(gIII) antibodies in the sera of experimentally challenged pigs strongly blocked the binding of the moMCAgIII:HRPO conjugate to the antigen-coated wells. Sera of 233 pigs from PRV-infected herds with virus neutralization (VN) titers of 1:4 or greater were tested. All except 2 of these sera had S/N values less than 0.7 and more than 175 had S/N values less than 0.1. Sixteen sera from fetal pigs with VN titers of 1:4 or greater had S/N values of 0.24 or less, but 2 sera with VN titers of 1:4 when tested 5 years prior to the PRV g92(gIII) blocking ELISA test gave false negative S/N values. Twenty-four of 29 pig sera from PRV-infected herds with VN titers less than 1:4 were positive for g92(gIII) antibodies, illustrating the sensitivity of the PRV g92(gIII) blocking ELISA test. Analyses on 7 sera with VN titers of 1:4-1:64 showed that titers obtained with the PRV g92(gIII) blocking ELISA test were from 2- to 16-fold greater than the VN titers. The accuracy and sensitivity of the PRV g92(gIII) blocking ELISA test was further demonstrated by analyses of 40 unknown sera supplied in the National Veterinary Services Laboratories 1988 PRV check test kit.

Cite

CITATION STYLE

APA

Kit, S., Awaya, Y., Otsuka, H., & Kit, M. (1990). Blocking ELISA to distinguish pseudorabies virus-infected pigs from those vaccinated with a glycoprotein gIII deletion mutant. Journal of Veterinary Diagnostic Investigation : Official Publication of the American Association of Veterinary Laboratory Diagnosticians, Inc, 2(1), 14–23. https://doi.org/10.1177/104063879000200104

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free