Abstract
We describe the repair of the postoperative left main stem stenosis of a 24-day old male patient who initially underwent arterial switch operation for dextro-transposition of the great arteries. The repair was facilitated by using an autologous left innominate vein patch, while there was a shortage of suitable repair material in this neonate. Postoperative echocardiogram prior to discharge confirmed a satisfactory flow through the left main stem and improved left ventricle function. © 2014 The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.