Values of Apparent Diffusion Coefficient and Lesion-to-Spinal Cord Signal Intensity in Diagnosing Solitary Pulmonary Lesions: Turbo Spin-Echo versus Echo-Planar Imaging Diffusion-Weighted Imaging

11Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective. This study is aimed at comparing the image quality and diagnostic performance of mean apparent diffusion coefficient (ADC) and lesion-to-spinal cord signal intensity ratio (LSR) derived from turbo spin-echo diffusion-weighted imaging (TSE-DWI) and echo-planar imaging- (EPI-) DWI in patients with a solitary pulmonary lesion (SPL). Methods. 33 patients with SPL underwent chest imaging using EPI-DWI and TSE-DWI with b=600 s/mm2 in free breathing. A comparison of the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) was drawn between the two techniques using a Wilcoxon signed-rank test. The interprotocol reproducibility between quantitative parameters of EPI-DWI and TSE-DWI was evaluated using a Bland-Altman plot. ADCs and LSRs derived from EPI-DWI and TSE-DWI were calculated and compared between malignant and benign groups using the Mann-Whitney test. Results. TSE-DWI had similar SNR and CNR compared with EPI-DWI. DR was significantly lower on TSE-DWI than EPI-DWI. ADC and LSR showed slightly higher values with TSE-DWI, while the Bland-Altman analysis showed unacceptable limits of agreement between the two sequences. ADC and LSR of both DWI techniques differed significantly between lung cancer and benign lesions (P<0.05). The LSR(EPI-DWI) showed the highest area under the curve (AUC=0.818), followed by ADC(EPI-DWI) (AUC=0.789), ADC(TSE-DWI) (AUC=0.781), and LSR(TSE-DWI) (AUC=0.748), respectively. Among these parameters, the difference in diagnostic accuracy was not statistically significant. Conclusions. TSE-DWI provides significantly improved image quality in patients with SPL as compared with EPI-DWI. However, there was no difference in diagnostic efficacy between these two techniques, according to ADC and LSR.

Cite

CITATION STYLE

APA

Lei, Q., Wan, Q., Liu, L., Hu, J., Zuo, W., Li, J., … Li, X. (2021). Values of Apparent Diffusion Coefficient and Lesion-to-Spinal Cord Signal Intensity in Diagnosing Solitary Pulmonary Lesions: Turbo Spin-Echo versus Echo-Planar Imaging Diffusion-Weighted Imaging. BioMed Research International, 2021. https://doi.org/10.1155/2021/3345953

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free