Localized Dielectric Loss Heating in Dielectrophoresis Devices

33Citations
Citations of this article
52Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Temperature increases during dielectrophoresis (DEP) can affect the response of biological entities, and ignoring the effect can result in misleading analysis. The heating mechanism of a DEP device is typically considered to be the result of Joule heating and is overlooked without an appropriate analysis. Our experiment and analysis indicate that the heating mechanism is due to the dielectric loss (Debye relaxation). A temperature increase between interdigitated electrodes (IDEs) has been measured with an integrated micro temperature sensor between IDEs to be as high as 70 °C at 1.5 MHz with a 30 Vpp applied voltage to our ultra-low thermal mass DEP device. Analytical and numerical analysis of the power dissipation due to the dielectric loss are in good agreement with the experiment data.

Cite

CITATION STYLE

APA

Kwak, T. J., Hossen, I., Bashir, R., Chang, W. J., & Lee, C. H. (2019). Localized Dielectric Loss Heating in Dielectrophoresis Devices. Scientific Reports, 9(1). https://doi.org/10.1038/s41598-019-55031-y