Bearing Fault Detection in Induction Motor Using Time Domain Analysis

  • S.DEORE K
  • A. KHANDEKAR M
N/ACitations
Citations of this article
14Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Approximately half of all operating costs in most processing and manufacturing operations can be attributed to maintenance. This is ample motivation for studying induction motor faults diagnosis and monitoring techniques that can reduce the maintenance costs. In the present scenario every industry need condition monitoring system to avoid unwanted faults in the process components. Vibration condition monitoring technique is widely used for fault detection. In this paper we analysed acceleration documented data of a 2 HP electric motor for bearing fault detection, for this we have use time domain analysis technique.

Cite

CITATION STYLE

APA

S.DEORE, K., & A. KHANDEKAR, M. (2014). Bearing Fault Detection in Induction Motor Using Time Domain Analysis. International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, 3(7), 10702–10707. https://doi.org/10.15662/ijareeie.2014.0307059