Use of capillary tubes and plate heat exchanger to validate U.S. Department of agriculture pasteurization protocols for elimination of Listeria monocytogenes in liquid egg products

15Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

D-values for a five-strain cocktail of Listeria monocytogenes in five different liquid egg products (whole egg, egg yolk, egg white, egg yolk + 5% sucrose + 5% NaCl, and egg yolk + 10% NaCl) were determined using 100-μl capillary tubes. The egg products were inoculated with approximately 1 x 1010 organisms/ml and heated in capillary tubes to temperatures ranging from 53 to 69°C for various time intervals. Using a pilot scale plate heat exchanger, the U.S. Department of Agriculture (USDA) protocols for pasteurization were also evaluated using egg products inoculated with approximately 1 x 107 L. monocytogenes/ml. Results of experiments with capillary tubes suggested that all processes would result in less than the 9D process recommended by USDA. Moreover, although pasteurization with a plate heat exchanger provided greater lethality than did capillary tubes, all products still received less than a 5.4D process. Hence, these results suggest that the current USDA protocol may not be adequate to assure a large margin of safety.

Cite

CITATION STYLE

APA

Michalski, C. B., Brackett, R. E., Hung, Y. C., & Ezeike, G. O. I. (2000). Use of capillary tubes and plate heat exchanger to validate U.S. Department of agriculture pasteurization protocols for elimination of Listeria monocytogenes in liquid egg products. Journal of Food Protection, 63(7), 921–925. https://doi.org/10.4315/0362-028X-63.7.921

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free