In-flight performance of pulse-processing system of the ASTRO-H/Hitomi soft x-ray spectrometer

  • Ishisaki Y
  • Yamada S
43Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

We summarize results of the initial in-orbit performance of the pulse shape processor (PSP) of the soft x-ray spectrometer instrument onboard ASTRO-H (Hitomi). Event formats, kind of telemetry, and the pulse-processing parameters are described, and the parameter settings in orbit are listed. The PSP was powered-on 2 days after launch, and the event threshold was lowered in orbit. The PSP worked fine in orbit, and there was neither memory error nor SpaceWire communication error until the break-up of spacecraft. Time assignment, electrical crosstalk, and the event screening criteria are studied. It is confirmed that the event processing rate at 100% central processing unit load is ∼200 c / s / array, compliant with the requirement on the PSP.

Cite

CITATION STYLE

APA

Ishisaki, Y., & Yamada, S. (2018). In-flight performance of pulse-processing system of the ASTRO-H/Hitomi soft x-ray spectrometer. Journal of Astronomical Telescopes, Instruments, and Systems, 4(01), 1. https://doi.org/10.1117/1.jatis.4.1.011217