Abstract
This prospective study included 32 patients undergoing cardiopulmonary bypass (CPB) for elective coronary artery bypass grafting correlates the respiratory end-tidal CO2 (ETCO2) during partial separation from CPB with cardiac output (CO) following weaning from CPB. After induction of general anesthesia, a pulmonary artery catheter was inserted for measurement of cardiac output by thermodilution. Patients were monitored using a 5-lead ECG, pulse oximeter, invasive blood pressure monitoring, rectal temperature probe, and end-tidal capnography. At the end of surgery, patients were weaned from CPB in a stepwise fashion. Respiratory ETCO2 and in-line venous oximetry were continuously monitored during weaning. The ETCO2 was recorded at quarter pump flow and after complete weaning from CPB. Following weaning from CPB, CO was measured by thermodilution. The CO values were correlated with the ETCO2 during partial bypass and following weaning from bypass. Regression analysis of ETCO2 at quarter-flow and post-bypass CO showed significant correlation (r = 0.57, p 30 mm Hg during partial CPB will always predict an adequate CO following weaning from CPB. An ETCO2 <30 mm Hg may denote either a low or a normal cardiac output and hence other predictive parameters such as SvO2 must be added.
Author supplied keywords
Cite
CITATION STYLE
Baraka, A. S., Aouad, M. T., Jalbout, M. I., Kaddoum, R. N., Khatib, M. F., & Haroun-Bizri, S. T. (2004). End-tidal CO2 for prediction of cardiac output following weaning from cardiopulmonary bypass. Journal of Extra-Corporeal Technology, 36(3), 255–257. https://doi.org/10.1051/ject/2004363255