Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration

32Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been introduced with little known regarding its efficacy. Methods: A retrospective study was conducted on patients referred for EBUS-TBNA who had LNs sampled using a 25G or 22G needle. A propensity score matching analysis was performed. After matching the groups, each LN was assessed for adequacy and final diagnosis. Non-diagnostic and benign lymphoid specimens were compared with repeat biopsy findings or long-term clinical and radiological follow-up. Results: A total of 158 LNs were included. An adequate sample was obtained in 92.4% (73/79) in the 25G group and 92.4% (73/79) in the 22G group (P=1). The 25G group diagnosed benign lymphoid tissue in 82.3% (65/79), granuloma in 7.6% (6/79) and malignancy in 2.5% (2/79). Six lymph nodes in the 25G group were non-diagnostic (7.6%). The 22G group diagnosed benign lymphoid tissue in 83.5% (66/79), granuloma in 3.8% (3/79) and malignancy in 5.1% (4/79). Six lymph nodes in the 22G group were non-diagnostic (7.6%). The sensitivity, specificity, negative predictive value (NPV) and diagnostic accuracy in the 25G group was 88.9% (95% CI, 51.8–99.7%), 100% (95% CI, 92.1–100%), 97.8% (95% CI, 87.6–99.7%) and 98.2% (95% CI, 90.1–100%), respectively. The sensitivity, specificity, NPV and diagnostic accuracy in the 22G group was 77.8% (95% CI, 40–97.2%), 100% (95% CI, 86.8–100%), 92.9% (95% CI, 79.3–97.8%) and 94.3% (95% CI, 80.8–99.3%), respectively. The 25G and 22G group were comparable in diagnostic accuracy (P=0.7). Conclusions: The 25G and 22G needle achieve comparable specimen adequacy and diagnostic accuracy in EBUS-TBNA.

Cite

CITATION STYLE

APA

Di Felice, C., Young, B., & Matta, M. (2019). Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration. Journal of Thoracic Disease, 11(8), 3643–3649. https://doi.org/10.21037/jtd.2019.04.20

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free