Abstract
Extraction procedures for in situ cosmogenic 14C (in situ 14C) from quartz require quantitative isotopic yields while maintaining scrupulous isolation from atmospheric and organic 14C. These time- and labor-intensive procedures are ripe for automation; unfortunately, our original automated in situ 14C extraction and purification systems, reconfigured and retrofitted from our original systems at the University of Arizona, proved less reliable than hoped. We therefore installed a fully automated stainless-steel system (except for specific borosilicate glass or fused-silica components) incorporating more reliable valves and improved actuator designs, along with a more robust liquid nitrogen distribution system. As with earlier versions, the new system uses a degassed lithium metaborate (LiBO2) flux to dissolve the quartz sample in an ultra-high-purity oxygen atmosphere, after a lower-temperature combustion step to remove atmospheric and organic 14C. We compared single-use high-purity Al2O3 against reusable 90 %Pt = 10 %Rh (Pt=Rh) sample combustion boats. The Pt=Rh boats heat more evenly than the Al2O3, reducing procedural blank levels and variability for a given LiBO2 flux. This lower blank variability also allowed us to trace progressively increasing blanks to specific batches of fluxes from our original manufacturer. Switching to a new manufacturer returned our blanks to consistently low levels on the order of (3.4±0.9)×104 14C atoms. We also analyzed the CRONUS-A intercomparison material to investigate sensitivity of extracted 14C concentrations to the temperature and duration of the combustion and extraction steps. Results indicate that 1 h combustion steps at either 500 or 600 °C yield results consistent with the consensus value of Jull et al. (2015), while 2 h at 600 °C results in loss of ca. 9% of the high-temperature 14C inventory. Results for 3 h extractions at temperatures ranging from 1050 to 1120 °C and 4.5 h at 1000 °C yielded similar results that agreed with the nominal value and published results from most laboratories. On the other hand, an extraction for 3 h at 1000 °C was judged to be incomplete due to a significantly lower measured concentration. Based on these results, our preferred technique is now combustion for 1 h at 500 °C followed by a 3 h extraction at 1050 _C. Initial analyses of the CoQtz-N intercomparison material at our lab yielded concentrations ca. 60% lower than those of CRONUS-A, but more analyses of this material from this and other labs are clearly needed to establish a consensus value.
Cite
CITATION STYLE
Lifton, N., Wilson, J., & Koester, A. (2023). Technical note: Studying lithium metaborate fluxes and extraction protocols with a new, fully automated in situ cosmogenic 14C processing system at PRIME Lab. Geochronology, 5(2), 361–375. https://doi.org/10.5194/gchron-5-361-2023
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.