Risk of fetal loss following amniocentesis or chorionic villus sampling in twin pregnancy: systematic review and meta-analysis

64Citations
Citations of this article
80Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: To assess the rate of fetal loss following amniocentesis or chorionic villus sampling (CVS) in twin pregnancy. Methods: MEDLINE, EMBASE and Cochrane databases were searched for studies reporting procedure-related complications following amniocentesis or CVS in twin pregnancy. The primary outcome was the rate of procedure-related fetal loss. The secondary outcomes were fetal loss occurring before 24 weeks of gestation and fetal loss occurring within 4 weeks after the procedure. Head-to-head meta-analyses were used to compare directly each outcome, between women undergoing amniocentesis and those not undergoing amniocentesis and between women undergoing CVS and those not undergoing CVS, and to compute pooled risk differences (RD) between women exposed and those not exposed to each invasive procedure. Additionally, meta-analyses of proportions were used to estimate the pooled rates of each of the three outcomes in women undergoing amniocentesis or CVS and in controls. Results: Sixteen studies (3419 twin pregnancies undergoing and 2517 not undergoing an invasive procedure) were included. Head-to-head meta-analyses comparing directly twin pregnancies undergoing and those not undergoing amniocentesis showed a higher risk for overall fetal loss in those undergoing amniocentesis (odds ratio (OR), 1.46 (P = 0.04); RD, 0.013 (P = 0.04)), while there was no difference in the risk of either fetal loss before 24 weeks of gestation (OR, 1.59 (P = 0.06); RD, 0.010 (P = 0.11)) or fetal loss within 4 weeks after the procedure (OR, 1.38 (P = 0.3); RD, 0.003 (P = 0.8)). Overall, the pooled rate of fetal loss was 2.4% (95% CI, 1.4–3.6%) in twin pregnancies undergoing amniocentesis compared with 2.4% (95% CI, 0.9–4.6%) in those not undergoing amniocentesis. Head-to-head meta-analyses directly comparing twin pregnancies undergoing and those not undergoing CVS showed no significant difference in either overall fetal loss (OR, 1.61 (P = 0.5); RD, 0.003 (P = 0.8)) or fetal loss before 24 weeks of gestation (OR, 1.61 (P = 0.5); RD, 0.003 (P = 0.8)). Overall, the pooled rate of fetal loss was 2.0% (95% CI, 0.0–6.5%) in twin pregnancies undergoing CVS compared with 1.8% (95% CI, 0.3–4.2%) in those not undergoing CVS. Conclusion: The risk of fetal loss following amniocentesis and CVS in twins is lower than reported previously and the rate of fetal loss before 24 weeks of gestation, or within 4 weeks after the procedure, did not differ from the background risk in twin pregnancy not undergoing invasive prenatal testing. These data can guide prenatal counseling for twin pregnancies undergoing invasive procedures. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.

Cite

CITATION STYLE

APA

Di Mascio, D., Khalil, A., Rizzo, G., Buca, D., Liberati, M., Martellucci, C. A., … D’Antonio, F. (2020, November 1). Risk of fetal loss following amniocentesis or chorionic villus sampling in twin pregnancy: systematic review and meta-analysis. Ultrasound in Obstetrics and Gynecology. John Wiley and Sons Ltd. https://doi.org/10.1002/uog.22143

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free