Tip detection-antegrade dissection and re-entry (TD-ADR) with integrated fluoroscopic and intravascular ultrasound images in chronic total occlusion: first case report of integrated TD-ADR technique

7Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background Tip detection-antegrade dissection and re-entry (TD-ADR) technique allows operators to accurately observe both guidewire tip direction and a true lumen in chronic total occlusion (CTO) lesions, while the torque direction of the guidewire on IVUS images does not invariably correspond to that on fluoroscopic images. Case summary A 41-year-old man with hypertension who smokes presented with sudden onset of dyspnoea, acute heart failure, and ischaemic findings on electrocardiogram; we performed percutaneous coronary intervention (PCI) for a sub-totally occluded mid-left anterior descending artery lesion. All antegrade wiring attempts failed to enter the distal true lumen followed by subintimal tracking and reentry technique. Since the lesion re-occluded the next day, we treated the lesion using a novel TD-ADR technique, termed the ‘integrated TD-ADR’, because of no interventional retrograde channel. This method integrates fluoroscopic and intravascular ultrasound (IVUS) images, ensuring congruence in the torque direction of the guidewire across both modalities and enabling vertical puncture of the stiff guidewire from the extraplaque space to the distal true lumen quickly and precisely. Final angiography showed good results. Five months later, coronary angiography showed that the lesion remained open. Discussion The integrated TD-ADR technique merges fluoroscopic and IVUS images, allowing operators to torque the guidewire in the same direction on both images. This approach might be more user-friendly than the original technique and has the potential to enhance the success rate of PCI in complex CTO cases. However, further investigations are warranted to address the clinical feasibility and applicability of this technique.

Cite

CITATION STYLE

APA

Tadano, Y., Kuramitsu, S., Sugie, T., Kanno, D., & Fujita, T. (2024). Tip detection-antegrade dissection and re-entry (TD-ADR) with integrated fluoroscopic and intravascular ultrasound images in chronic total occlusion: first case report of integrated TD-ADR technique. European Heart Journal - Case Reports, 8(8). https://doi.org/10.1093/ehjcr/ytae378

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free