Performance evaluation of a plate type (HTST) milk pasteurizer

  • CHAUDHARY D
  • CHAUDHARI A
N/ACitations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

The performance of plate type (HTST) milk pasteurizer was analyzed in a commercial dairy plant having installed\rcapacity of 1.0 lakh lit./day. The purpose of the analysis was to determine the regeneration efficiency and utility usage includes\rsteam, chilled water and electrical energy, in the milk pasteurization processing line. In this dairy plant, the experiment was carried\rout and results in 89.34 per cent regeneration efficiency achieved. Theoretical and actual steam consumption was determined at\rrate of 155.72 kg/hr and 156.48 kg/hr, respectively. Chilled water utilization was found to be 25.11 m3 /hr i.e. 2.36 times than milk flow\rrate. Power consumption for milk pasteurization was found to be 16.09 kWh per hour.

Cite

CITATION STYLE

APA

CHAUDHARY, D. A., & CHAUDHARI, A. G. (2015). Performance evaluation of a plate type (HTST) milk pasteurizer. RESEARCH JOURNAL OF ANIMAL HUSBANDRY AND DAIRY SCIENCE, 6(2), 130–134. https://doi.org/10.15740/has/rjahds/6.2/130-134