Abstract
Introduction: This in-vitro study aimed to test the accuracy and reproducibility in detection of incipient occlusal caries and treatment decision making using unenhanced visual-tactile technique and low level magnification by the use of loupes and surgical operating microscope (SOM). Methodology: Sixty extracted human posterior teeth were assessed by two examiners using ICDAS- II index and CPI- TN probe, with and without magnification. Histopathology was used as gold standard for diagnosis of caries and treatment decision making. Inter and intra examiner reproducibility was determined using Kappa statistics. Results: Intraobserver reproducibility for caries detection using surgical operating microscope ranged from average to good (0.4-0.63). Inter-examiner reproducibility values for treatment decision making using experimental techniques such as unaided (0.40), Loupes (0.51) & SOM (0.63) were similar.
Author supplied keywords
Cite
CITATION STYLE
Sisodia, N., & Manjunath, M. K. (2014). Impact of low level magnification on incipient occlusal caries diagnosis and treatment decision making. Journal of Clinical and Diagnostic Research, 8(8). https://doi.org/10.7860/JCDR/2014/8533.4742