Influence of minor geometric features on Stirling pulse tube cryocooler performance

4Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Minor geometric features and imperfections are commonly introduced into the basic design of multi-component systems to simplify or reduce the manufacturing expense. In this work, the cooling performance of a Stirling type cryocooler was tested in different driving powers, cold-end temperatures and inclination angles. A series of Computational Fluid Dynamics (CFD) simulations based on a prototypical cold tip was carried out. Detailed CFD model predictions were compared with the experiment and were used to investigate the impact of such apparently minor geometric imperfections on the performance of Stirling type pulse tube cryocoolers. Predictions of cooling performance and gravity orientation sensitivity were compared with experimental results obtained with the cryocooler prototypes. The results indicate that minor geometry features in the cold tip assembly can have considerable negative effects on the gravity orientation sensitivity of a pulse tube cryocooler.

Cite

CITATION STYLE

APA

Fang, T., Spoor, P. S., Ghiaasiaan, S. M., & Perrella, M. (2017). Influence of minor geometric features on Stirling pulse tube cryocooler performance. In IOP Conference Series: Materials Science and Engineering (Vol. 278). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/278/1/012140