Abstract
This study assessed the performance of rainwater-harvesting systems installed for selected public utilities in the northern provinces of Vietnam where rainwater was collected, stored in stainless steel tanks, and treated with a complex filtration unit and Ultraviolet (UV) disinfection system (full system). Results from an operation of over 5 years show that the untreated rainwater could not be used directly for drinking purposes as it was contaminated with bacteria (total coliforms TC = 200–300 CFU/100 ml, Pseudomonas aeruginosa PA = 40–160 CFU/100 ml), and turbidity = 2–4 NTU. Most of the heavy metals detected were found below the standard limits. Phenol and its derivatives were detected occasionally as higher than the standard value (1 μg/L). After treatment, all parameters met the drinking water standards. The capital costs of the rainwater systems were approximately US$200/m3 and US$180/m3 for a full system and simplified system (without complex filtration unit), respectively, while the operation and maintenance (O&M) costs were 3 cents/L and 0.8 cents/L on average for a full system and simplified one, correspondingly.
Author supplied keywords
Cite
CITATION STYLE
Tran, S. H., Dang, H. T. T., Dao, D. A., Nguyen, V. A., Nguyen, L. T., Nguyen, V. A., & Han, M. (2021). On-site rainwater harvesting and treatment for drinking water supply: assessment of cost and technical issues. Environmental Science and Pollution Research, 28(10), 11928–11941. https://doi.org/10.1007/s11356-020-07977-0