Comparative trial of Dexon (polyglycolic acid), collagen, and silk sutures in ophthalmic surgery

12Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

The tissue reaction, absorption, and handling properties of Dexon synthetic absorbable sutures, which are made from polymerized hydroxyacetic acid, were compared with those of silk and collagen in 5i eye operations, consisting mainly of cataract extractions and squint corrections. There was no significant difference between the sutures as regards degree of tissue reaction. The Dexon sutures were very strong and the knots held well. The sizes used in this series were found to be a little too thick and stiff for use in microsurgery; smaller sizes would be easier to use and still remain strong enough. The Dexon was reliably absorbed in 5 weeks on average. No serious adverse reactions were seen with any of the sutures. Dexon was as well tolerated as the control sutures but had the advantage over silk of being absorbed and over collagen of containing no foreign protein.

Cite

CITATION STYLE

APA

Chatterjee, S. (1975). Comparative trial of Dexon (polyglycolic acid), collagen, and silk sutures in ophthalmic surgery. British Journal of Ophthalmology, 59(12), 736–740. https://doi.org/10.1136/bjo.59.12.736

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free