Feasibility of endoscopic ultrasound-guided hepaticogastrostomy using a 22-gauge needle

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This study aimed to evaluate the feasibility of performing endoscopic ultrasound-guided hepaticogastrostomy using a 22-gauge fine-needle aspiration needle. This was a single-center retrospective study. Fourteen patients who underwent endoscopic ultrasound-guided hepaticogastrostomy with a 22-gauge fine-needle aspiration needle were examined. Fourteen eligible patients were included in this study. The age of patients ranged from 55 to 93 years, with a median of 76 years. Of patients with existing underlying diseases, there were 8 cases of pancreatic cancer (57.1%), 2 cases of metastatic liver tumor (14.3%), 2 cases of bile duct stones (14.3%), 1 case of hilar cholangiocarcinoma (7.1%), and 1 case of gallbladder cancer (7.1%). Regarding gastrointestinal anatomy, there were 11 cases (78.6%) of normal and 3 cases (21.4%) of gastric resection with Roux-en-Y. Reasons for endoscopic ultrasound-guided hepaticogastrostomy were duodenal obstruction in 7 cases (50.0%), surgically altered anatomy in 3 cases (21.4%), and 4 cases (28.6%) of failed endoscopic retrograde cholangiopancreatography. Technical success was achieved in 11 cases (78.6%). Subsequently, 11 cases of technical success were analyzed. There were 5 cases of puncturing B2 (45.5%). The puncture bile duct diameter ranged from 3.1 to 5.7 mm, with a median of 4.4 mm. endoscopic ultrasound-guided antegrade procedures was combined with endoscopic ultrasound-guided hepaticogastrostomy in 2 cases (18.2%). Clinical success was achieved in all the cases. The procedure time ranged from 15 to 93 minutes, with a median duration of 35 minutes. Regarding the type of stent placed in hepaticogastrostomy, a plastic stent was placed in 10 cases (90.9%) and a metal stent was placed in 1 case (9.1%). Early adverse events occurred in 4 cases (36.4%), and all of these cases developed biliary peritonitis, late adverse events occurred in 1 case (9.1%), this was biloma. A change to a 0.025-inch guidewire during the procedure was required in 8 cases (72.7%). Esophageal puncture was not performed. endoscopic ultrasound-guided hepaticogastrostomy using a 22-gauge fine-needle aspiration needle is effective. However, in 72.7% of the cases started using the 0.018-inch guidewire, the guidewire was exchanged for a 0.025-inch guidewire during procedure.

Cite

CITATION STYLE

APA

Takahashi, K., Ohyama, H., Ouchi, M., Kan, M., Nagashima, H., Iino, Y., … Kato, N. (2022). Feasibility of endoscopic ultrasound-guided hepaticogastrostomy using a 22-gauge needle. Medicine (United States), 101(44), E31545. https://doi.org/10.1097/MD.0000000000031545

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free