Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis

6Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The aim of the present study is to compare the early and mid-term clinical and hemodynamic results of the aortic valve replacement (AVR) with a St Jude Medical Regent 19-mm prosthesis (SJMR-19) versus Carpentied-Edwars bovine pericardial 19-mm valve (CE-19). Methods: Between January 2002 and January 2012, 265 patients (Group I) and 58 patients (Group II) with underwent AVR with a SJMR-19 and CE-19 respectively. There were no significant differences between groups regarding the demographic and preoperative echocardiographic data. Thirty-six patients in Group I and 4 in Group II required annulus enlargement in association or not with septal myectomy. The mean follow-up was 34 ± 18.5 months (range 5-60 months). Results: There were 14 (5.3 %) hospital deaths in Group I versus 4 (6.8 %) in Group II (p = 0.86). The multivariate logistic regression analysis identified the LVEF ≤ 35 % (p = 0.001), combined operation (p = 0.0005), CPB (p = 0.033), age (p = 0.011), annulus enlargement (p = 0.0009), reoperation (p = 0.039) and chronic renal failure (p = 0.011) as strong predictors for early postoperative death. Within 1 year after surgery peak pulmonary artery pressure, interventricular septal and left ventricular posterior wall thickness decreased significantly in both groups. The M-TPG was 15.7 ± 6.5 mmHg in Group I versus 17 ± 7 mmHg in Group II (p = 0.19). The multivariate regression analysis revealed the annulus enlargement (p = 0.018), small EOAi (p = 0.00004), postoperative LVMi (p = 0.0001) and BSA (p = 0.019) as strong predictors for higher M-TPG. The postoperative LVMi was 119 ± 22.5 gm/m2 in Group I and 122 ± 22 gm/m2 in Group II (p = 0.37), significantly lower than the respective preoperative values 162.5 ± 34 gm/m2 (Group I) and 168 ± 30 gm/m2 (Group II). The actuarial survival and cumulative free-reoperation actuarial survival at 5 years follow-up were 96.7 and 94.5 % respectively in Group I and 97 and 91 % in Group II.. There were non significant differences between groups regarding the actuarial survival and cumulative free-reoperation survival. The Cox model identified the older age (p = 0.022), LVEF ≤ 35 % (p = 0.009), reoperation (p = 0.018), combined surgery (p = 0.00075) and annulus enlargement (p = 0.033) as strong predictors for poor actuarial free-reoperation survival. Conclusions: Both the SJMR-19 and CE-19 offers excellent postoperative clinical and hemodynamic outcome in patients with small aortic annulus. The LV hypertrophy and transvalvular gradients are reduced significantly indenpendently of the employed SJMR-19 or CE-19 prosthesis. Our data support recent suggestions that small valve size does not influence intermediate free-reoperation survival. The CE-19 is an excellent alternative to SJMR-19 in old patients.

Cite

CITATION STYLE

APA

Prifti, E., Bonacchi, M., Ademaj, F., Giunti, G., Esposito, G., Baboci, A., … Vanini, V. (2015). Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis. Journal of Cardiothoracic Surgery, 10(1). https://doi.org/10.1186/s13019-015-0361-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free