Comparison of haemoglobin assessments by HemoCue and two automated haematology analysers in young Laotian children

59Citations
Citations of this article
128Readers
Mendeley users who have this article in their library.

Abstract

background Haemoglobin (Hb) assessment by Hemocue is used widely for anaemia screening in both adults and children. However, few studies have compare the diagnostic accuracy of Hemocue with an automated haematology analyser in young children. Aim To compare Hb concentrations by Hemocue Hb30 and two automated haematology analysers in young children in rural communities of Lao PDR. Methods Capillary blood was collected from 6-month-old to 23-month-old children (n=1487) for determinatio of Hb concentration by Hemocue Hb301. On the same day, venous blood was collected for complete blood count using one of two haematology analysers (XT-1800i, Sysmex, and BC-3000Plus, Mindray Medical International). In a subsample of children (n=129), venous Hb was also measured by HemoCue Hb301. Agreement between the two methods was estimated using Bland-Altman plots. results Mean capillary Hb by Hemocue was significantly higher than mean venous Hb by haematology analysers combined (108.4±10.3 g/L vs 102.3±13.1 g/L; P<0.001), resulting in a significantly lower anaemia prevalence (Hb <110 g/L) by Hemocue (53.7% vs 73.9%; P<0.001). The Bland-Altman assessment of agreement showed a bias of 6.1 g/L and limits of agreement were −11.5 g/L to 23.7 g/L. Mean venous Hb concentration by Hemocue Hb301 (113.6±14.0 g/L) was significantly higher than mean capillary Hb concentration by Hemocue Hb301 (110.0±10.7; P=0.03 g/L), which in turn was significant higher than mean venous Hb concentration by the Mindray BC-3000Plus (102.3±17.4 g/L). Conclusion Capillary and venous Hb concentrations assessed by Hemocue Hb301 showed poor agreement compared with venous Hb by automated haematology analysers, resulting in significantly different anaemia prevalences.

Cite

CITATION STYLE

APA

Hinnouho, G. M., Barffour, M. A., Wessells, K. R., Brown, K. H., Kounnavong, S., Chanhthavong, B., … Hess, S. Y. (2018). Comparison of haemoglobin assessments by HemoCue and two automated haematology analysers in young Laotian children. Journal of Clinical Pathology, 71(6), 532–538. https://doi.org/10.1136/jclinpath-2017-204786

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free