Methylmalonic acid measured in plasma and urine by stable-isotope dilution and electrospray tandem mass spectrometry

100Citations
Citations of this article
61Readers
Mendeley users who have this article in their library.

Abstract

Background: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization is robust and allows accurate measurement of both low- and high-molecular weight components of complex mixtures. We developed a LC-MS/MS method for the analysis of methylmalonic acid (MMA), a biochemical marker for inherited disorders of propionate metabolism and acquired vitamin B12 deficiency. Methods: We added 1 nmol of the internal standard MMA-d3 to 500 μL of plasma or 100 μL of urine before solid-phase extraction. After elution with 18 mol/L formic acid, the eluate was evaporated, and butyl ester derivatives were prepared with 3 mol/L HCl in nbutanol at 65 °C for 15 min. For separation, we used a Supelcosil LC-18, 33 x 4.6 mm column with 60:40 (by volume) acetonitrile: aqueous formic acid (1 g/L) as mobile phase. The transitions m/z 231 to m/z 119 and m/z 234 to m/z 122 were used in the selected reaction monitoring mode for MMA and MMA-d3, respectively. The retention time of MMA was 2.2 min in a 3.0-min analysis, without interference of a physiologically more abundant isomer, succinic acid. Results: Daily calibrations between 0.25 and 8.33 nmol in 0.5 mL exhibited consistent linearity and reproducibility. At a plasma concentration of 0.12 μmol/L, the signal-to-noise ratio for MMA was 40:1. The regression equation for our previous gas chromatography-mass spectrometry (GC-MS) method (y) and the LC-MS/MS method (x) was: y = 1.030x - 0.032 (S(y|x = 1.03 μmol/L; n = 106; r = 0.994). Inter- and intraassay CVs were 3.8-8.5% and 1.3-3.4%, respectively, at mean concentrations of 0.13, 0.25, 0.60, and 2.02 μmol/L. Mean recoveries of MMA added to plasma were 96.9% (0.25 μmol/L), 96.0% (0.60 μmol/L), and 94.8% (2.02 μmol/L). One MS/MS system used only overnight (7.5 h) replaced two GC-MS systems (30 instrument-hours/day) to run 100-150 samples per day, with reductions of total cost (supplies plus equipment), personnel, and instrument time of 59%, 14%, and 75%, respectively. Conclusions: This method is well suited for large-scale MMA testing (≥100 samples per day) where a shorter analytical time is highly desirable. Reagents are less expensive than the anion-exchange/cyclohexanol-HCl method, and sample preparation of batches up to 100 specimens is completed in less than 8 h and is automated. (C) 2000 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Magera, M. J., Helgeson, J. K., Matern, D., & Rinaldo, P. (2000). Methylmalonic acid measured in plasma and urine by stable-isotope dilution and electrospray tandem mass spectrometry. Clinical Chemistry, 46(11), 1804–1810. https://doi.org/10.1093/clinchem/46.11.1804

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free