Abstract

An approach to carry out chemical reactions using aggressive gases in situ in a transmission electron microscope (TEM), at ambient pressures of 1.5 bar using a windowed environmental cell, called a nanoreactor, is presented here. The nanoreactor coupled with a specially developed holder with platinum tubing permits the usage of aggressive chemicals like hydrochloric acid (HCl). © 2013 Royal Society of Chemistry.

Cite

CITATION STYLE

APA

Malladi, S., Shen, C., Xu, Q., de Kruijff, T., Yücelen, E., Tichelaar, F., & Zandbergen, H. (2013). Localised corrosion in aluminium alloy 2024-T3 using in situ TEM. Chemical Communications, 49(92), 10859–10861. https://doi.org/10.1039/c3cc46673f