Engineered or incidental particles may contain endotoxin from contaminated environments associated with generation, production, or handling activities. Endotoxins are ubiquitous contaminants that may yield false positive responses in immunological assays if present. The purpose of this study was to develop a sterilization method for removal of endotoxin from clinically relevant wear particles isolated from metal-on-metal (MoM) hip implant lubricant. In this case, the goal of particle sterilization was to sufficiently reduce endotoxin levels to acceptable levels for sensitive biological assays while retaining the physical and chemical characteristics of the original particles. Optimization of treatment with 0.05 NaOH in 50% ethanol successfully achieved a 5-log (>99.999%) reduction of endotoxin content while retaining the size and chemistry of MoM hip implant wear particles. Using the optimized method, the concentration of endotoxin was reduced from 161,000 to 1.19 EU/mL. As particle types can vary, sterilization strategies will also differ to optimize endotoxin removal while retaining key particle characteristics. To our knowledge, this study represents the first published sterilization method for clinically relevant MoM hip implant wear particles isolated from serum-rich lubricant.
CITATION STYLE
Fung, E. S., Unice, K. M., Paustenbach, D. J., Finley, B. L., & Kovochich, M. (2018). Methods for Sterilizing Clinically Relevant Wear Particles Isolated from Metal-on-Metal Hip Implants. Scientific Reports, 8(1). https://doi.org/10.1038/s41598-017-18239-4
Mendeley helps you to discover research relevant for your work.