Abstract
We have designed and characterized a simple Rayleigh-surface acoustic wave-based micropump, integrated directly with a fully enclosed 3D microfluidic system, which improves significantly the pumping efficiency within a coupled fluid whilst maintaining planar integration of the micropump and microfluidics. We achieve this by exploiting the Rayleigh-scattering angle of surface acoustic waves into pressure waves on contact with overlaid fluids, by designing a microfluidic channel aligned almost co-linearly with the launched pressure waves and by minimizing energy losses by reflections from, or absorption within, the channel walls. This allows the microfluidic system to remain fully enclosed - a pre-requisite for point-of-care applications - removing sources of possible contamination, whilst achieving pump efficiencies up to several orders of magnitude higher than previously reported, at low operating powers of 0.5 W.
Cite
CITATION STYLE
Rimsa, R., Smith, A. J., Wälti, C., & Wood, C. D. (2017). A planar surface acoustic wave micropump for closed-loop microfluidics. Applied Physics Letters, 111(23). https://doi.org/10.1063/1.5007701
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.