Abstract
This paper presents a novel hall sensor fault detection and fault-tolerant control method for a high-speed permanent magnet synchronous motor (PMSM) drive system. A phase locked loop (PLL) type position estimator is used with a conventional interpolation based rotor position estimator to reduce position errors due to misalignment of hall sensors. The expected trigger time of hall sensor's output is used for detecting hall sensor fault condition and the PLL type position estimator is reconfigured for fault-tolerant control at the hall sensor fault condition. The proposed method can minimize current ripples during the transition from sensored control using hall sensors to sensorless control. Experimental results have been proposed to prove the validity of the proposed method.
Cite
CITATION STYLE
Jang, M.-H., & Lee, K.-W. (2013). Hall Sensor Fault Detection and Fault-Tolerant Control of High-Speed PMSM Drive System. The Transactions of the Korean Institute of Power Electronics, 18(3), 205–210. https://doi.org/10.6113/tkpe.2013.18.3.205