PENENTUAN LIMIT DETEKSI PENGUJIAN GAS HIDROGEN KLORIDA (HCl) DARI EMISI SUMBER TIDAK BERGERAK MENGGUNAKAN KROMATOGRAFI ION

  • Puji Lestari R
  • Gifrianto R
  • Hadi A
N/ACitations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

ABSTRAK Pengujian kadar gas hidrogen klorida (HCl) dari emisi sumber tidak bergerak yang dilakukan oleh laboratorium-laboratorium lingkungan di Indonesia mengacu pada SNI 19-7117.8-2005. Di dalam metode spektrofotometri tersebut digunakan beberapa bahan berbahaya dan beracun (B3) antara lain merkuri tiosianat, metanol,dan asam perklorat. Laboratorium P3KLL menentukan limit deteksi terhadap metode uji yang diadopsi dari JIS K 0107-1995 menggunakan instrumen kromatografi ion DIONEX ICS5000. Instrumen IC5000 dilengkapi dengan detektor konduktivitas, penggunaan EGC (Eluent Generator Cartridge) yang ditambahkan dengan Carbonate Removal, dan mempunyai ukuran loop sampel 50μL. Kolom separator IonPac AS18 dengan kolom penjaga IonPAc AG18 dan 0 suppressor ASRS-II digunakan pada suhu 35 C. Larutan yang digunakan sebagai eluen adalah H2O (DHL< 1μS/cm) pada laju alir 1 L/menit. Tahapan kegiatan terdiri dari persiapan, pengambilan contoh uji dan validasi metoda. Pengambilan contoh uji dilakukan tiga kali di insenerator sebagai bagian dari tahapan validasi yaitu mengkonfirmasi rentang uji. Dari hasil kajian tersebut, diperoleh LoD = 0,6 mg/Nm 3 , LoQ = 2 mg/Nm 3 , dan LoL= 129 mg/Nm 3 , dimana JIS K 0107-1995 "Methods for Determination of Hydrogen Chloride in Flue Gas"memiliki rentang kerja 0,6-130 mg/Nm 3. Disimpulkan bahwa metode terverifikasi sesuai tujuan dan laboratorium P3KLL mampu menunjukkan kompetensinya dalam menerapkan metode pengujian Hcl tersebut. Kata kunci: hidrogen klorida, emisi sumber tidak bergerak, kromatografi ion ABSTRACT Determination of hydrogen chloride (HCl) in flue gas was conducted by the environmental laboratories in Indonesia according to the method of SNI 19-7117.8-2005. Within this spectrophotometry method, there are several toxic reagents were used such as mercury thiocyanate, methanol, and perchloric acid. Laboratory of P3KLL determined the limit detection from adopted method of JISK 0107-1995 using ion chromatography instrument, DIONEX ICS5000. The IC5000 equipped with conductivity detector, EGC (Eluen Generator Cartridge), Carbonate Removal, and 50μL sample loop. IonPac AS18 column, IonPAc Ag18 guard column and 0 ASRS-II suppressor were used at 35 C. The eluent was H2O (EC<1μS/cm) at a flow rate of 1 L/min. The sampling was conducted three times in incinerator as part of method validation i.e. confirmation of analytical range.The result showed that LoD of 0,6 mg/Nm 3 , LoQ of 2 mg/Nm 3 and LoL of 129 mg/Nm 3 were obtained, whereas JIS K 0107-1995 "Methods for Determination of Hydrogen Chloride in Flue Gas"having a working range of 0,6-130 mg/Nm 3. It is concluded that the method was verified according the goal, and the laboratory of P3KLL was able to show its competency in order to apply the testing method of HCl.

Cite

CITATION STYLE

APA

Puji Lestari, R., Gifrianto, R. G., & Hadi, A. H. (2017). PENENTUAN LIMIT DETEKSI PENGUJIAN GAS HIDROGEN KLORIDA (HCl) DARI EMISI SUMBER TIDAK BERGERAK MENGGUNAKAN KROMATOGRAFI ION. Jurnal Ecolab, 11(1), 32–41. https://doi.org/10.20886/jklh.2017.11.1.32-41

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free