Abstract
Usually, conventional electron paramagnetic resonance (EPR) spectroscopy and imaging employ a microwave cavity operating at X-band, i.e., with an excitation frequency of around 9.6 GHz, and this remains the most popular mode for the magnetic characterization of lithium batteries to date. Here, we provide the first low-frequency EPR investigations with respect to monitoring the metallic lithium structures in solid-state pouch cell batteries. We show that L-band, i.e., a microwave frequency of around 1.01 GHz, is an invaluable method to probe the electrode components directly through a standard pouch cell using aluminum-laminated film for packaging without opening the battery. These results offer a new approach for monitoring the nucleation of micrometric and submicrometric lithium particles, such as dendritic lithium structures, and is an important step in the development of reliable solid-state batteries.
Cite
CITATION STYLE
Dutoit, C. E., Soleti, R., Doux, J. M., Pelé, V., Boireau, V., Jordy, C., … Vezin, H. (2025). Innovative L-band electron paramagnetic resonance investigation of solid-state pouch cell batteries. Magnetic Resonance, 6(1), 113–118. https://doi.org/10.5194/mr-6-113-2025
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.