Repeatability and reliability of quantitative fundus autofluorescence imaging in patients with early and intermediate age-related macular degeneration

27Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Quantification of fundus autofluorescence has only recently become available. We report our findings on the evaluation of the repeatability and reliability of quantitative fundus autofluorescence (qAF) measurements in patients with early and intermediate age-related macular degeneration (AMD), using the first approved and commercially available instrument. Methods: A total of 43 eyes of 22 patients (aged between 52 and 84 years) diagnosed with early and intermediate AMD were included. All eyes were imaged at day 1, 3 months and 6 months using a modified scanning laser ophthalmoscope, equipped with an internal fluorescent reference. Mean qAF values were calculated for the fovea and for each concentric ring of the Delori pattern. Repeatability and reliability were calculated using Bland–Altman analysis and intraclass correlation (ICC). Results: The mean patient age was 73.5 ± 7.9 years. Sixteen patients (73%) were female. qAF repeatability of the eight segments in the middle ring of the Delori pattern (qAFM8) for between sessions was ±8.2%. Agreement at 3- and 6-month follow-up in eyes without retinal changes was ±8.3% and ±9.8%, respectively. Reliability of qAFM8 was high for all images acquired [ICC = 0.98 (CI: 0.96–0.99), 0.97 (0.93–0.99) and 0.98 (0.92–0.99)]. Agreement at 3- and 6-month follow-up in eyes with retinal changes was ±18.1% and ±20.2%, respectively. Intraclass correlation (ICC) was slightly lower in eyes with retinal changes at 0.93 (0.84–0.97) and 0.96 (0.91–0.98), respectively. Conclusions: Quantitative autofluorescence shows excellent repeatability and reliability as well as follow-up agreement in patients with early and intermediate AMD without retinal changes. This is relevant when conducting longitudinal studies using qAF.

Cite

CITATION STYLE

APA

Reiter, G. S., Told, R., Baratsits, M., Hecht, A., Schlanitz, F. G., Sacu, S., & Schmidt-Erfurth, U. (2019). Repeatability and reliability of quantitative fundus autofluorescence imaging in patients with early and intermediate age-related macular degeneration. Acta Ophthalmologica, 97(4), e526–e532. https://doi.org/10.1111/aos.13987

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free