Comparison of surgical outcomes between excisional goniotomy using the kahook dual blade and istent trabecular micro-bypass stent in combination with phacoemulsification

42Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare 6-month surgical outcomes of patients who underwent phacoemulsification (Phaco) combined with iStent implantation (iStent) versus excisional goniotomy using Kahook Dual Blade (KDB). Methods: Retrospective comparative case series of 58 iStent-Phaco eyes and 44 KDB-Phaco eyes operated upon by a single surgeon between 2016 and 2018. Preoperative, intraoperative, and postoperative intraocular pressure (IOP) and IOP-lowering medication data were collected. The primary outcome was the proportion of eyes using ≥1 fewer IOP-lowering medication at Month 6 while maintaining IOP ≤ 18 mmHg. Results: Baseline IOP was 17.2 (standard error 0.7) in the KDB-Phaco group using a mean of 1.9 (0.2) medications; at Month 6, mean IOP was 14.8 mmHg P=0.002) on 1.0 (0.2) medications (P<0.002). Baseline IOP was 16.7 (0.4) in the iStent-Phaco group using a mean of 1.4 (0.1) medications; at Month 6, mean IOP was 14.2 mmHg (P<0.002) on 1.4 (0.1) medications P=0.374). Changes in IOP and medications were not significantly different between groups (P>0.05). Significantly more KDB-Phaco eyes than iStent- Phaco eyes (43.2% vs 17.2%, P=0.004) were using ≥1 fewer medications while maintaining IOP ≤18 mmHg at Month 6. Adverse events were uncommon and similar in nature and frequency between groups with the exception that more KDB-Phaco eyes than iStent- Phaco eyes (8 [18.2%] versus 1 [1.7%]) experienced an IOP elevation presumed to be related to steroid use. Conclusion: KDB-Phaco and iStent-Phaco provided comparable IOP and medication reductions. The proportion of eyes able to discontinue 1 or more medications while maintaining IOP ≤ 18 mmHg was significantly greater in eyes undergoing KDB-Phaco.

Cite

CITATION STYLE

APA

Lee, D., King, J., Thomsen, S., Hirabayashi, M., & An, J. (2019). Comparison of surgical outcomes between excisional goniotomy using the kahook dual blade and istent trabecular micro-bypass stent in combination with phacoemulsification. Clinical Ophthalmology, 13, 2097–2102. https://doi.org/10.2147/OPTH.S224109

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free