Decay of electric charge on corona charged polyethylene

93Citations
Citations of this article
49Readers
Mendeley users who have this article in their library.

Abstract

This paper describes a study on the surface potential decay of corona charged low density polyethylene (LDPE) films. A conventional corona charging process is used to deposit charge on the surface of film and surface potential is measured by a compact JCI 140 static monitor. The results from corona charged multilayer sample reveal that the bulk process dominates charge decay. In addition, the pulsed-electro-acoustic (PEA) technique has been employed to monitor charge profiles in corona charged LDPE films. By using the PEA technique, we are able to monitor charge migration through the bulk. Charge profiles in corona charged multilayer sample are consistent with surface potential results. Of further significance, the charge profiles clearly demonstrate that double injection has taken place in corona charged LDPE films. © 2007 IOP Publishing Ltd.

Cite

CITATION STYLE

APA

Xu, Z., Zhang, L., & Chen, G. (2007). Decay of electric charge on corona charged polyethylene. Journal of Physics D: Applied Physics, 40(22), 7085–7089. https://doi.org/10.1088/0022-3727/40/22/033

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free