Tip Detection–Antegrade Dissection and Re-Entry With New Puncture Wire in CTO Intervention: Revolution Through 3D-Wiring

29Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The authors devised the tip detection (TD) method and developed AnteOwl WR intravascular ultrasound to standardize intravascular ultrasound–based 3-dimensional wiring for intraplaque tracking in chronic total occlusion (CTO)–percutaneous coronary intervention (PCI). The TD method also allowed antegrade dissection and re-entry (ADR). Combining TD-ADR with Conquest Pro 12 Sharpened Tip (CP12ST) wire, a new ADR wire with the strongest penetration force developed to date, enabled re-entry anywhere except calcification sites. Objectives: This study investigated the efficacy and feasibility of TD-ADR by comparison of procedural outcomes with Stingray-ADR in CTO-PCI. Methods: Twenty-seven consecutive CTO cases treated by TD-ADR with CP12ST wire between August 2021 and April 2023 and 27 consecutive CTO cases treated by Stingray-ADR with Conquest 8-20 (CP20) wire between March 2018 and July 2021 were retrospectively enrolled as the TD-ADR by CP12ST wire group and Stingray-ADR by CP20 wire group, respectively, from 4 facilities that could share technical information on these procedures. Results: The success rate of the ADR procedure was significantly improved (27 of 27 cases [100%] vs 18 of 27 cases [67%], respectively; P = 0.002) and total procedural time was significantly reduced (median procedural time: 145.0 [Q1-Q3: 118.0-240.0] minutes vs 185.0 [Q1-Q3: 159.5-248.0] minutes, respectively; P = 0.028) in the TD-ADR by CP12ST wire group compared to the Stingray-ADR by CP20 wire group. There were few in-hospital major adverse cardiac and cerebrovascular events or no complications in either group. Conclusions: TD-ADR by CP12ST wire can standardize highly accurate ADR in CTO-PCI.

Cite

CITATION STYLE

APA

Tanaka, K., Okamura, A., Yoshikawa, R., Tsuchikane, E., Ishikawa, M., Suzuki, S., … Watanabe, H. (2024). Tip Detection–Antegrade Dissection and Re-Entry With New Puncture Wire in CTO Intervention: Revolution Through 3D-Wiring. JACC: Asia, 4(5), 359–372. https://doi.org/10.1016/j.jacasi.2023.11.017

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free