Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study

2Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Objective: The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software. Methods: Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the OneCeph® application and Dolphin imaging software®. Two independent observers identified seventeen landmarks and measured fourteen cephalometric measurements at an interval of. Interobserver and intraobserver reliability were evaluated using the intraclass correlation coefficient. Student's t-test was used to compare the means of two measurement methods for observer 1 and observer 2. Additionally, the time taken to complete the cephalometric measurements was also compared between the two methods. Results: Good (ICC 0.75-0.90) to excellent (ICC 0.90-1.00) interobserver and intraobserver reliability was observed for all hard and soft tissue measurements with both methods. No significant differences were found between the two measurement methods for both observers (p<0.05). OneCeph application took significantly more time to complete the analysis than Dolphin imaging software (p<0.001). Conclusion: Cephalometric measurements made through a smartphone-based application showed good to excellent interobserver and intraobserver reliability and are comparable with the computer-based software. Therefore, it can be recommended for clinical use. The time taken to complete the cephalometric measurements was more with a smartphone-based application (OneCeph application) compared to computer-based software (Dolphin imaging software).

Cite

CITATION STYLE

APA

Chugh, V. K., Bhatia, N. K., Shastri, D., Shankar, S. P., Singh, S., & Sardana, R. (2023). Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study. Turkish Journal of Orthodontics, 36(2), 94–100. https://doi.org/10.4274/TurkJOrthod.2022.2022.60

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free