A study on dosimetric characterization of direct yellow 12 dye at high radiation γ-dose

5Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

Aqueous solution of oxygenated Direct yellow 12 dye has been evaluated spectrophotometrically as a possible gamma rays dosimeter. The neutral (pH-7), alkaline (pH-12.5) and acidic (pH-5.5) aqueous solution of the dye were prepared and exposed to various gamma doses. Absorption spectra of unirradiated and irradiated solutions were recorded at 400 nm peak. The increase in absorbance with the increase in irradiation dose was observed from 1 to 6 kGy. The stability response of the dye solution for different environmental conditions such as temperature (low & high), light and darkness were investigated during post irradiation storage for ten days. The dye solution showed high stability in darkness for the studied period. The optical density of the dye solution was found to be decreased at high temperature storage.

Cite

CITATION STYLE

APA

Batool, J., Shahid, S. A., Akhtar, R. N., Naz, A., Yaseen, M., Ullah, I., … Shakir, I. (2012). A study on dosimetric characterization of direct yellow 12 dye at high radiation γ-dose. Bulletin of the Korean Chemical Society, 33(7), 2265–2268. https://doi.org/10.5012/bkcs.2012.33.7.2265