Abstract
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1deg; of rotation around the mediolateral axis at a load of 500 N. ©2011 British Editorial Society of Bone and Joint Surgery.
Cite
CITATION STYLE
Berber, O., Amis, A. A., & Day, A. C. (2011). Biomechanical testing of a concept of posterior pelvic reconstruction in rotationally and vertically unstable fractures. Journal of Bone and Joint Surgery - Series B, 93 B(2), 237–244. https://doi.org/10.1302/0301-620X.93B2.24567
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.