Abstract
We performed a longitudinal analysis of plasma samples obtained from 4 patients with Ebola virus (EBOV) disease (EVD) to determine the relationship between the real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR)-based threshold cycle (Ct) value and the presence of infectious EBOV. EBOV was not isolated from plasma samples with a Ct value of >35.5 or >12 days after onset of symptoms. EBOV was not isolated from plasma samples in which anti-EBOV nucleoprotein immunoglobulin G was detected. These data demonstrate the utility of interpreting qRT-PCR results in the context of the course of EBOV infection and associated serological responses for patient-management decisions.
Author supplied keywords
Cite
CITATION STYLE
Spengler, J. R., McElroy, A. K., Harmon, J. R., Ströher, U., Nichol, S. T., & Spiropoulou, C. F. (2015). Relationship between Ebola Virus Real-Time Quantitative Polymerase Chain Reaction-Based Threshold Cycle Value and Virus Isolation from Human Plasma. Journal of Infectious Diseases, 212, S346–S349. https://doi.org/10.1093/infdis/jiv187