Automaticity and conduction properties of bio-artificial pacemakers assessed in an in vitro monolayer model of neonatal rat ventricular myocytes

12Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims A better understanding of the ionic mechanisms for cardiac automaticity can lead to better strategies for engineering bio-artificial pacemakers. Here, we attempted to better define the relative contribution of If and IK1 in the generation of spontaneous action potentials (SAPs) in cardiomyocytes (CMs). Methods and results Monolayers of neonatal rat ventricular myocytes (NRVMs) were transduced with a recombinant adenovirus (Ad) to express a gating-engineered HCN1 construct (HCN1-ΔΔΔ) for patch-clamp and multielectrode array (MEA) recordings. Single NRVMs exhibited a bi-phasic response in the generation of SAPs (62.6 ± 17.4 b.p.m., Days 1-2; 194.3 ± 12.3 b.p.m., Days 3-4; 73 quiescent, Days 9-10). Although automaticity time-dependently decreased and subsequently ceased, If remained fairly stable (-5.2 ± 1.1 pA/pF, Days 1-2;-5.1 ± 1.4 pA/pF, Days 7-8;-4.3 ± 1.3 pA/pF, Days 13-14). In contrast, IK1 declined rapidly (from-16.9 ± 2.7 pA/pF on Days 1-2 to-4.4 ± 1.6 pA/pF on Days 5-6). Maximum diastolic potential/resting membrane potential (r = 0.89) and action potential duration at 50 (APD50, r = 0.73) and 90 (APD90, r = 0.75) but not the firing rate (r =-0.3) were positively correlated to the IK1. Similarly, monolayer NRVMs ceased to spontaneously fire after long-term culture. Ad-HCN1-ΔΔΔ transduction restored pacing in silenced individual and monolayer NRVMs but with reduced conduction velocity and field potential amplitude. Conclusion We conclude that the combination of IK1 and If primes CMs for bio-artificial pacing by determining the threshold. However, If functions as a membrane potential oscillator to determine the basal firing frequency. Future engineering of automaticity in the multicellular setting needs to have conduction taken into consideration. Published on behalf of the European Society of Cardiology. © The Author 2010.

Author supplied keywords

Cite

CITATION STYLE

APA

Chan, Y. C., Tse, H. F., Siu, C. W., Wang, K., & Li, R. A. (2010). Automaticity and conduction properties of bio-artificial pacemakers assessed in an in vitro monolayer model of neonatal rat ventricular myocytes. Europace, 12(8), 1178–1187. https://doi.org/10.1093/europace/euq120

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free