A compact tetrahedral microphone array is used to measure several controlled sound fields and compare the analysis of spatial room impulse responses with two methods: spatial decomposition method (SDM) and IRIS, a commercial system based on sound intensity vector analysis. Results suggest that the spatial accuracy of both methods is similar and in most cases the error is comparable to the localization uncertainty of human listeners. Furthermore, a listening test is conducted comparing three 3D-sound fields and their SDM auralizations. Results suggest that the similarity of the auralized and original sound fields depends on the target room and stimulus.
CITATION STYLE
Amengual Garí, S. V., Lachenmayr, W., & Mommertz, E. (2017). Spatial analysis and auralization of room acoustics using a tetrahedral microphone. The Journal of the Acoustical Society of America, 141(4), EL369–EL374. https://doi.org/10.1121/1.4979851