Risk of Interprosthetic Femur Fracture Is Associated with Implant Spacing—A Biomechanical Study

2Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

Background: Ipsilateral revision surgeries of total hip or knee arthroplasties due to periprosthetic fractures or implant loosening are becoming more frequent in aging populations. Implants in revision arthroplasty usually require long anchoring stems. Depending on the residual distance between two adjacent knee and hip implants, we assume that the risk of interprosthetic fractures increases with a reduction in the interprosthetic distance. The aim of the current study was to investigate the maximum strain within the femoral shaft between two ipsilateral implants tips. Methods: A simplified physical model consisting of synthetic bone tubes and metallic implant cylinders was constructed and the surface strains were measured using digital image correlation. The strain distribution on the femoral shaft was analyzed in 3-point- and 4-point-bending scenarios. The physical model was transferred to a finite element model to parametrically investigate the effects of the interprosthetic distance and the cortical thickness on maximum strain. Strain patterns for all parametric combinations were compared to the reference strain pattern of the bone without implants. Results: The presence of an implant reduced principal strain values but resulted in distinct strain peaks at the locations of the implant tips. A reduced interprosthetic distance and thinner cortices resulted in strain peaks of up to 180% compared to the reference. At low cortical thicknesses, the strain peaks increased exponentially with a decrease in the interprosthetic distance. An increasing cortical thickness reduced the peak strains at the implant tips. Conclusions: A minimum interprosthetic distance of 10 mm seems to be crucial to avoid the accumulation of strain peaks caused by ipsilateral implant tips. Interprosthetic fracture management is more important in patients with reduced bone quality.

Cite

CITATION STYLE

APA

Mühling, M., Sandriesser, S., Glowalla, C., Herrmann, S., Augat, P., & Hungerer, S. (2023). Risk of Interprosthetic Femur Fracture Is Associated with Implant Spacing—A Biomechanical Study. Journal of Clinical Medicine, 12(9). https://doi.org/10.3390/jcm12093095

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free