Direct detection of monoclonal free light chains in serum by use of immunoenrichment-coupled MALDI-TOF mass spectrometry

42Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.
Get full text

Abstract

BACKGROUND: Free light chain (FLC) quantification is the most analytically sensitive blood-based method commercially available to diagnose and monitor patients with plasma cell disorders (PCDs). However, instead of directly detecting monoclonal FLCs (mFLCs), FLC assays indirectly assess clonality based on quantifying ĸ and λ FLCs and determination of the к/λ FLC ratio. Often an abnormal FLC ratio is the only indication of a PCD, and confirmation by a direct method increases diagnostic confidence. The aim of this study was to develop an analytically sensitive method for direct detection of mFLCs. METHODS: Patient sera (n = 167) previously assessed by nephelometric FLC quantification and immunofixation electrophoresis (IFE) were affinity enriched for IgG, IgA, and total and free ĸ and λ light chains and subjected to MALDI-TOF MS. Relative analytical sensitivity of these methods was determined using serially diluted sera containing mFLCs. RESULTS: In sera with abnormal FLC ratios (n = 127), 43% of monoclonal proteins were confirmed by IFE, 57% by MALDI-TOF MS without FLC enrichment, and 87% with FLC enrichment MALDI-TOF MS. In sera with normal FLC ratios (n = 40), the FLC MALDI-TOF MS method identified 1 patient with an mFLC. Serial dilution and analysis of mFLC containing sera by IFE, nephelometry, and FLC MALDI-TOF MS demonstrated that FLC MALDI-TOF MS analysis had the highest analytical sensitivity. CONCLUSIONS: FLC immunoenrichment coupled to MALDI-TOF MS enables direct detection of mFLCs and significantly increases the confirmation of abnormal serum FLC ratios over IFE and MALDI-TOF MS without FLC enrichment, thereby providing added confidence for diagnosing FLC PCDs.

Cite

CITATION STYLE

APA

Sepiashvili, L., Kohlhagen, M. C., Snyder, M. R., Willrich, M. A. V., Mills, J. R., Dispenzieri, A., & Murray, D. L. (2019). Direct detection of monoclonal free light chains in serum by use of immunoenrichment-coupled MALDI-TOF mass spectrometry. Clinical Chemistry, 65(8), 1015–1022. https://doi.org/10.1373/clinchem.2018.299461

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free