A Novel Evaluation Criterion for the Rapid Estimation of the Overcharge and Deep Discharge of Lithium-Ion Batteries Using Differential Capacity

13Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Differential capacity dQ/dU (capacitance) can be used for the instant diagnosis of battery performance in common constant current applications. A novel criterion allows state-of-charge (SOC) and state-of-health (SOH) monitoring of lithium-ion batteries during cycling. Peak values indicate impeding overcharge or deep discharge, while dSOC/dU = dU/dSOC = 1 is close to “full charge” or “empty” and can be used as a marker for SOC = 1 (and SOC = 0) at the instantaneous SOH of the aging battery. Instructions for simple state-of-charge control and fault diagnosis are given.

Cite

CITATION STYLE

APA

Kurzweil, P., Frenzel, B., & Scheuerpflug, W. (2022). A Novel Evaluation Criterion for the Rapid Estimation of the Overcharge and Deep Discharge of Lithium-Ion Batteries Using Differential Capacity. Batteries, 8(8). https://doi.org/10.3390/batteries8080086