Abstract
We describe a point-of-use (POU) ultraviolet (UV) disinfection technology, the UV Tube, which can be made with locally available resources around the world for under $50 US. Laboratory and field studies were conducted to characterize the UV Tube's performance when treating a flowrate of 5 L/min. Based on biological assays with MS2 coliphage, the UV Tube delivered an average fluence of 900 ± 80J/m2 (95% CI) in water with an absorption coefficient of 0.01 cm-1. The residence time distribution in the UV Tube was characterized as plug flow with dispersion (Peclet Number = 19.7) and a mean hydraulic residence time of 36s. Undesirable compounds were leached or produced from UV Tubes constructed with unlined ABS, PVC, or a galvanized steel liner. Lining the PVC pipe with stainless steel, however, prevented production of regulated halogenated organics. A small field study in two rural communities in Baja California Sur demonstrated that the UV Tube reduced E. coli concentrations to less than 1/100 ml in 65 out of 70 samples. Based on these results, we conclude that the UV Tube is a promising technology for treating household drinking water at the point of use. © IWA Publishing 2008.
Author supplied keywords
Cite
CITATION STYLE
Brownell, S. A., Chakrabarti, A. R., Kaser, F. M., Connelly, L. G., Peletz, R. L., Reygadas, F., … Nelson, K. L. (2008). Assessment of a low-cost, point-of-use, ultraviolet water disinfection technology. Journal of Water and Health, 6(1), 53–65. https://doi.org/10.2166/wh.2007.015
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.