Purification and separation of rare earth elements from ccfl with extraction chromatography

1Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

In this study, Amberite XAD-7HP was used as the solvent-impregnated resin to separate each REE from the standard solution, which was mixed with the REEs (e.g., La Eu, Tb, Y and Ba). About 100 ppm of each of the REEs was separated from DI water using extraction chromatography. REEs were separated by extraction chromatography using Amberite XAD-7HP resin, the changes in the pH values of the HCl and HClO 4 were between 0.2 N and 5 N, and the extraction rate of the solution was between 0.5 and 3 ml/min. The La solution with the separated REEs was leached. The solid-state REEs were annealed between 1083K. The extraction result was analyzed with ICP-AES and an X-ray diffractometer. Each REE was successfully separated with HCl and HClO4 with pH values between 0.1 N and 3 N and with extraction rate between 1.0 m/min and 3.0 m/min.

Cite

CITATION STYLE

APA

Kim, J. G. (2015). Purification and separation of rare earth elements from ccfl with extraction chromatography. Archives of Metallurgy and Materials, 60(2), 1529–1533. https://doi.org/10.1515/amm-2015-0166

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free