Multicenter performance evaluation and reference range determination of a new one-stage factor VIII assay

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: We conducted a multicenter evaluation of a new one-stage factor VIII (FVIII) assay (Roche Diagnostics), intended for the quantitative assessment of FVIII activity. We evaluated the analytical performance of the FVIII assay on the cobas t 711 analyzer. Methods: Experiments performed at three laboratories used 3.2% citrated residual or commercially purchased plasma samples. Five human plasma pools and two controls were used to determine assay within-run and within-laboratory precision, and total reproducibility; coefficients of variation (CVs) and/or standard deviations (SDs) were calculated. Lot-to-lot variability and method comparison (vs Coagulation FVIII Deficient Plasma/Dade Actin FS Activated PTT reagent/Standard Human Plasma Calibrator on the Sysmex CS-5100 analyzer; Siemens Healthineers) were evaluated by Passing–Bablok and Deming regression, respectively, and Pearson's r calculated. Assay-specific reference range was determined using 199 fresh plasma samples from healthy adults, not receiving anticoagulants. Results: Across sites, SDs for repeatability were 0.016–0.046 for samples with ≤1.0 international units (IU)/dL FVIII activity; CVs were 0.9%–3.8% for samples with >1.0 IU/dl activity. Among samples with mean FVIII activity 0.344–133 IU/dl, good intermediate precision (SD 0.020 for samples with 0.344 IU/dl activity; CV 1.8%–4.7%) and good total reproducibility (CV 2.0%–13.3%) were observed. The FVIII assay showed excellent lot-to-lot variability (Pearson's r =.999) and good correlation with the comparator assay (Pearson's r =.993–.996). The reference range for FVIII activity was 82.2−218.0 IU/dl. Conclusion: The one-stage FVIII assay demonstrated robust analytical performance on the cobas t 711 analyzer, supporting its use in routine laboratory practice.

Cite

CITATION STYLE

APA

Lowe, A. E., Jones, R., Kitchen, S., Geisen, U., Rozsnyai, G., Jilma, P., & Quehenberger, P. (2022). Multicenter performance evaluation and reference range determination of a new one-stage factor VIII assay. Journal of Clinical Laboratory Analysis, 36(4). https://doi.org/10.1002/jcla.24294

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free