Noninvasive quantification of cerebrovascular pressure changes using 4D Flow MRI

19Citations
Citations of this article
44Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Hemodynamic alterations are indicative of cerebrovascular disease. However, the narrow and tortuous cerebrovasculature complicates image-based assessment, especially when quantifying relative pressure. Here, we present a systematic evaluation of image-based cerebrovascular relative pressure mapping, investigating the accuracy of the routinely used reduced Bernoulli (RB), the extended unsteady Bernoulli (UB), and the full-field virtual work-energy relative pressure ((Formula presented.) WERP) method. Methods: Patient-specific in silico models were used to generate synthetic cerebrovascular 4D Flow MRI, with RB, UB, and (Formula presented.) WERP performance quantified as a function of spatiotemporal sampling and image noise. Cerebrovascular relative pressures were also derived in 4D Flow MRI from healthy volunteers ((Formula presented.)), acquired at two spatial resolutions (dx = 1.1 and 0.8 mm). Results: The in silico analysis indicate that accurate relative pressure estimations are inherently coupled to spatial sampling: at dx = 1.0 mm high errors are reported for all methods; at dx = 0.5 mm (Formula presented.) WERP recovers relative pressures at a mean error of 0.02 ± 0.25 mm Hg, while errors remain higher for RB and UB (mean error of −2.18 ± 1.91 and −2.18 ± 1.87 mm Hg, respectively). The dependence on spatial sampling is also indicated in vivo, albeit with higher correlative dependence between resolutions using (Formula presented.) WERP (k = 0.64, R2 = 0.81 for dx = 1.1 vs. 0.8 mm) than with RB or UB (k = 0.04, R2 = 0.03, and k = 0.07, R2 = 0.07, respectively). Conclusion: Image-based full-field methods such as (Formula presented.) WERP enable cerebrovascular relative pressure mapping; however, accuracy is directly dependent on utilized spatial resolution.

Cite

CITATION STYLE

APA

Marlevi, D., Schollenberger, J., Aristova, M., Ferdian, E., Ma, Y., Young, A. A., … Nordsletten, D. A. (2021). Noninvasive quantification of cerebrovascular pressure changes using 4D Flow MRI. Magnetic Resonance in Medicine, 86(6), 3096–3110. https://doi.org/10.1002/mrm.28928

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free