Corrosion behaviour of SS316L in artificial blood plasma in presence of amoxicillin

10Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

An investigation about the corrosion resistance of SS316L alloys in artificial blood plasma environments in presence and absence of amoxicillin has been carried out by using electrochemical techniques. Tested alloys included 18% Cr, 12% Ni, 2.5% Mo, <0.03 C, balanceiron, using artificial blood plasma solution. Electrochemical techniques included potentiodynamic polarization curves, linear polarization resistance and AC impedance spectroscopy. Different techniques have shown that generally speaking, SS316L alloys show a more corrosion resistance in artificial blood plasma in the presence of 100 ppm amoxicillin than in the presence of 50 ppm of amoxicillin and in the absence of amoxicillin. Their corrosion resistance is increased as the quantity of amoxicillin is increased in artificial blood plasma.

Cite

CITATION STYLE

APA

John Mary, S., & Rajendran, S. (2013). Corrosion behaviour of SS316L in artificial blood plasma in presence of amoxicillin. Portugaliae Electrochimica Acta, 31(1), 33–40. https://doi.org/10.4152/pea.201301033