Laboratory evaluation of the broad-spectrum antibacterial efficacy of a low-irradiance visible 405-nm light system for surface-simulated decontamination

8Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Lighting systems which use visible light blended with antimicrobial 405-nm violet-blue light have recently been developed for safe continuous decontamination of occupied healthcare environments. This paper characterises the optical output and antibacterial efficacy of a low irradiance 405-nm light system designed for environmental decontamination applications, under controlled laboratory conditions. Methods: In the current study, the irradiance output of a ceiling-mounted 405-nm light source was profiled within a 3×3×2 m (18 m3) test area; with values ranging from 0.001-2.016 mWcm-2. To evaluate antibacterial efficacy of the light source for environmental surface decontamination, irradiance levels within this range (0.021-1 mWcm-2) at various angular (Δ ϴ=0-51.3) and linear (∆s=1.6-2.56 m) displacements from the source were used to generate inactivation kinetics, using the model organism, Staphylococcus aureus. Additionally, twelve bacterial species were surface-seeded and light-exposed at a fixed displacement below the source (1.5 m; 0.5 mWcm-2) to demonstrate broad-spectrum efficacy at heights typical of high touch surfaces within occupied settings. Results: Results demonstrate that significant (P≤0.05) inactivation was successfully achieved at all irradiance values investigated, with spatial positioning from the source affecting inactivation, with greater times required for inactivation as irradiance decreased. Complete/near-complete (≥93.28%) inactivation of all bacteria was achieved following exposure to 0.5 mWcm-2 within exposure times realistic of those utilised practically for whole-room decontamination (2-16 h). Conclusion: This study provides fundamental evidence of the efficacy, and energy efficiency, of low irradiance 405-nm light for bacterial inactivation within a controlled laboratory setting, further justifying its benefits for practical infection control applications.

Cite

CITATION STYLE

APA

Sinclair, L. G., Dougall, L. R., Ilieva, Z., McKenzie, K., Anderson, J. G., MacGregor, S. J., & Maclean, M. (2023). Laboratory evaluation of the broad-spectrum antibacterial efficacy of a low-irradiance visible 405-nm light system for surface-simulated decontamination. Health and Technology, 13(4), 615–629. https://doi.org/10.1007/s12553-023-00761-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free